Best Biobase 800 Test/Hour Bk-800 Automated Chemistry Analyzer

Best~BIOBASE 800 tests/hour BK-800 Auto Chemistry Analyzer Features:180 Sample positions.200  Reagent positions. 160 Reaction cuvettes.800 Tests / Hour Features:1. Fully automated, Discrete, Random access,STAT priority,real-time dual wavelength.2. Total open&n

Featured Products

Best~BIOBASE 800 tests/hour BK-800 Auto Chemistry Analyzer
Best~Biobase 800 Tests/Hour Bk-800 Auto Chemistry Analyzer
 

Features:
180 Sample positions.

200  Reagent positions. 

160 Reaction cuvettes.

800 Tests / Hour

 

Features:

1. Fully automated, Discrete, Random access,STAT priority,real-time dual wavelength.

2. Total open setting of items, supported different reagents from different countries.

3. Reversed optics and imported photo sensor make sure the precision of detection results.

4. Microsring injector imported from Germany assures the veracity of a trace of samples, 

sample step by 0.1 UL, reagent step by0.5 UL

5. 24 hour non-stop working, convenient emergency function with inserting emergency at random.

6. Implementing analysis of ultra-trace reaction solution to 100 UL, and saving more reagents.

7. Discrete cuvette, preventing from cross-infection, and be washed and reused, making sure accurate result and save cost.

8. Perfect self-detection function makes sure the analyzer in order and accurate result.

9. Software is easy to learn and use. And test report can be printed.

10. Perfect function of quality control management is convenient for users to manage the clinical test result.

11. Detecting in the whole reaction process with reaction curve, convenient for users to monitor thoroughly 

and scientifically analyze the detection data.

12. Supporting software can implement the function of detecting surplus reagent through liquid level 

induction of reagent probe.

 

Technical Parameters

Overall 

Performance 

 Model 

 BK-800(EMERALD)

 Type 

 Discrete, Fully automatic 

 Throughput 

 800 tests per hour 

 Analysis Method 

 End-point, Fixed-time, Rate, Turbidimetry

 Programming Items 

 Programmable for any test items 

Certification 

 CE, FDA, ISO9001, ISO14001, ISO13485 

Sample unit 

 Sample Position

 180 samples, double disk design, including 60 samples for 

 calibration/quality dribbling refrigerated

 Sample Tubes

 Original blood collection tube, micro tube, plastic tube, etc

 Sample Types 

 Serum, plasma, urine, etc

 Sample Volume 

 2ul ~70ul (0.1ul stepping) 

 Sample Probe 

 Having liquid level induction function, 

 ensuring the accuracy of adding sample 

 Probe Cleaning 

 Automatic washing both interior and exterior ,

 cross contamination rate < 0.1%

 Analysis Items 

 Analyzing maximally 100 items at the same time 

Reagent unit 

Reagent Position 

 200 reagent positions, dual-tray design

 Wash Solution

 Washing solution can be installed in any position, including needle, 

 stir bar washing solution and water bath disinfectant

 Reagent Volume 

 20ul~350ul, 0.5ul increment

Temperature Control 

 Continuous 2ºC~8ºC cooling within 24 hours 

 Reagent Probe 

 Having liquid level induction function, ensuring the accuracy of adding 

 reagent. Inventory checking 

 Probe Cleaning 

 Automatic washing both interior and exterior 

Reaction 

Unit 

 Reaction Volume

 150ul-550ul

 Reaction Temperature

 37ºC

 Temperature System

 Water bath,Real-time temperature display

 Cuvettes 

 160 positions with permanent hard glass 

 cuvettes (optical path length 5mm) 

 Stirrer 

 Independent stir bar, nanotechnology, highly polished, 

 automatic frequency conversion

 Cleaning 

 Automatic water cleaning and drying system 

 System Adjustment 

 System can record the blank value and get more accurate result 

 by deducting blank base value of each cuvette 

Optical 

System 

 Light Source 

 Halogen lamp, lamp can be auto sleep and wake up

 Receiver 

 Holographic flat field concave grating diode array detection

 Wavelength Range 

 16 wavelengths from 340 to 800nm

 Linear Range 

 -0.3000~3.3000 Abs

 Stray Light

 < 0.1% or Abs > 3.0

Calibration 

and QC 

 Calibration Method

 Linear calibration:K factor, two- and multiple linear  Nonlinear

 Calibration: spline, polynomial, Logarithm, etc 

 Quality Control 

 Auto QC,cooled QC positions

Software 

 Emergency Function 

 Emergency sample can be placed in the sample tray at any time 

 Software 

 Windows 7/8/10 or above, LIS system available

 Online

 Full bi-directional communication possible

 Data Processing 

 Having reaction curve detection and data display function 

 in the whole process 

Others 

 Water Consumption

 Deionized water , <45 L/hour

 Power Supply 

 110/220v ±10%, 50/60Hz

 Package Size

 1720*1200*1430mm

 Gross Weight 

 600Kg