Current Transformer Analyzer CT PT Excitation Curve Test

DescriptionCTA-1000 Series CT Analyzer automatically determines all relevant current transformer values and compares the results with the selected standard. The device evaluates the current transformer as per the IEC or IEEE standard within seconds with the push of a button.  It facilitates fast and economical on-site testi

Featured Products

Description
Current Transformer Analysis Device CT PT Excitation Curve Testing

CTA-1000 Series CT Analyzer automatically determines all relevant current transformer values and compares the results with the selected standard. The device evaluates the current transformer as per the IEC or IEEE standard within seconds with the push of a button.  

It facilitates fast and economical on-site testing and calibration of metering and protection current transformers. Manufacturers of current transformers, high voltage transformers and switchgear also use the CT Analyzer for tests during development and production.

 

 Product Feature    

1.Wide range of measurements; 

2.Easy to use.One click can complete tests

3.Highest measurement accuracy: 0.05% / 2 min when calibrating on site;

4.Automatic evaluation according to IEC and IEEE standards; 

5.Short commissioning times (duration of the automatic test < 2min); 

6.Excellent workplace safety - Tests run at max. 180V;

7.Very small and lightweight (<9kg ),easy to transport for on-site testing; 

8.Professional pull box design, easy to carry, anti-vibration.

Current Transformer Analysis Device CT PT Excitation Curve Testing
 

     Applications    

The following values can be determined using the CT/PT Analyzer:
    1. CT:
    (1) CT accuracy for different burdens 
    (2) CT ratio and phase-angle accuracy 
    (3) CT excitation characteristics
    (4) CT inductance (saturated and unsaturated)

    (5) Burden impedance

    (6) CT winding resistance

    (7) CT polarity 

    (8)  ALF and FS (direct and indirect)
    (9) CT residual magnetism

    2. PT:
    (1) PT excitation and saturation
    (2) Burden impedance
    (3) Winding resistance Saturated and non-saturated inductance
    (4) PT polarity

 Product Parameters   

TypeCTA-1000C
UsageCT,PT
Output0~180Vrms,12Arms,36A(peak value)
Voltage measurement accuracy±0.1%
CT RatioRange1~40000
accuracy±0.05%
PT RatioRange1~40000
accuracy±0.05%
PhaseRange±2min
accuracy0.5min
DC resistanceRange0~300Ω
accuracy0.2%±2mΩ
BurdenRange0~1000VA
accuracy0.2%±0.02VA
Power supplyAC220V±10%,50Hz
Environmental Conditions

Operating temperature: -10ºC~50ºC
Humidity:≤90%

Weight and DimensionsDimensions:365mm×300mm×165mm
Weight:9.5kg

Standard Accesories:

No.

Name

Qty

1

Host

1

2

Up-flow reactor(optional)

1

3

Power line

1

4

Red test line

1

5

Yellow test line

1

6

Green test line

1

7

High current test line(optional)

2

8

Control line(optional)

1

9

Ground wire

1

10

Alligator clip

4

11

Alligator clip

2

12

U type insert

4

13

Thermal printing paper

4

14

U disk

1

15

Protective tube

5

16

Special screwdriver for protective tube

1

17

Quality testing report

1

18

Instruction manual

1

19

Aluminum alloy packing box

1


Current Transformer Analysis Device CT PT Excitation Curve Testing
Current Transformer Analysis Device CT PT Excitation Curve Testing
Current Transformer Analysis Device CT PT Excitation Curve Testing
Current Transformer Analysis Device CT PT Excitation Curve Testing
Current Transformer Analysis Device CT PT Excitation Curve Testing
Current Transformer Analysis Device CT PT Excitation Curve Testing
Current Transformer Analysis Device CT PT Excitation Curve Testing
Current Transformer Analysis Device CT PT Excitation Curve Testing
Current Transformer Analysis Device CT PT Excitation Curve Testing
Current Transformer Analysis Device CT PT Excitation Curve Testing

 

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours